Hadatomo™ Z Photoacoustic Microscope WEL5200

MODEL IMAGE

Noninvasive, High-Speed 3D Imaging of Blood Vessels in the Dermis

The Hadatomo™ Ζ simultaneously images the oxygen saturation of blood vessels with two wavelengths of optical ultrasound, and images the skin texture, pores, and skin structures such as sebaceous glands with ultrasound.

Feature

Multi-modality Imaging

Ultrasound that visualizes the skin structure based on the differences in tissue hardness, and optical ultrasound, which selectively images melanin and blood vessels based on their absorption characteristics, are integrated into one system.

Quasi-real-time imaging

The photoacoustic wave images and the ultrasonic wave images are measured simultaneously, with a minimum measurement time of 40 seconds (Range: 6 mm x 3 mm x 3 mm (depth)) and maximum time of 210 seconds (Range: 6 mm x 6 mm x 3 mm (depth)).

High-resolution images obtained with easy operation

An ultrasonic sensor developed especially for this system provides a high-resolution crosssection view. Focus points can be easily located by observing the cross-section.

Flexible design with easy operation and portability

The compactly designed system, equipped with a measurement unit mounted on a flexible arm, is installed on a system unit with caster wheels, easy to set up to measure various parts of the body.

Label-free

Applying a small amount of water (acoustic coupling agent) to the measurement area is enough for measurement.
Non-invasive measurement is possible without any contrast agent.

Acquires data for 3-dimensional imaging

Measurement data are displayed as 2-dimensional cross-section images in real-time, and acquisition of 3-dimensional data images is possible. 3-dimensional image analysis is possible with customer-provided rendering software.

Specification

System

Measurement 2D(Tomography), 3D
Sampling frequency 500 MHz
Dimensions Approx. 610 (W) × 730 (D) × 1,400 (H)
Weight < 135 kg

3D image

Measurement area(x, y) (1) 6 x 3 mm (2) 6 x 6 mm
Measurement depth(z) 3 mm (designated signal acquisition range)
Scanning step 15 μm / 30 μm
Measurement time(15 μm) (1) 210 s (2) 420 s
Measurement time(30 μm) (1) 70 s (2) 140 s

2D image

Measurement area(x, ) 6 mm
Measurement depth(z) 3 mm
Image resolution 15 μm / 30 μm
Flame rate 1 fps

Photoacoustic imaging

Wavelength (A) 532/556 nm (B) 575/650 nm *1
Horizontal image resolution 15 μm
Axial image resolution 12 μm *2
Pulse energy
(A)Below 16 µJ/pulse
(B)Below 16 µJ/pulse (575 nm)
Below 14 µJ/pulse (650 nm) *3
Pulse width Below 10 ns
Repetition rate 1000 Hz *4

Ultrasound imaging

Horizontal image display 15 μm
Axial image display 12 μm *5
Transmission repetition rate 1000 Hz

Ultrasound sensor

Center frequency 60 MHz ± 20 %

*1: Select one of the following sets: 532/556 nm, or 575/650 nm
*2: Depending on ultrasound velocity
*3: Averaged value
*4: 1000 Hz per 1 wavelength
*5: Depending on ultrasound velocity

  • Specifications may change without notification.
  • This product is categorized as a Scientific Instrument. It is not approved for use in diagnosis of diseases.