WM2000TA 2ch Temperature/Voltage Measurement Unit
Wireless Data Logger
AirLogger™ WM2000 Series
Measures Temperatures, Voltages of Rotating/Moving Objects
Features
Real-time Simultaneous Measurement at a Maximum of 200 points
By utilizing the advantage of wireless measurement, a maximum of 200 points (100 units) can be measured simultaneously in real time.
* By utilizing the advantage of wireless measurement, a maximum of 200 points (100 units) can be measured simultaneously in real time.
* When sampling time is less than 1 sec, max 30 units can be connected.
Compact Body Housing 2 channels
High density mounting technology makes units even smaller and enables 2 channels to be installed in 1 unit. It contributes to space saving at installation sites and improves efficiency of operation.
Contains Two Functions, Temperature and Voltage Measurement
Temperature or voltage can be measured on each channel, providing flexible measurement in various environments required by diverse applications.
Wider Targets of Measurement with Voltage-Output Type Sensors
Various kinds of physical quantity can be measured such as humidity, pressure, wind speed or illumination by attaching voltage-output type sensors.
Expansion of Measurement Environment
The measurement area will be extended to diverse environments such as area near water or hot temperature area using water-proof attachment or heat-resistant case.
Main Functions
Number of simultaneously connected units | Max 100 units/system | |
---|---|---|
2 ch Temperature/Voltage Measurement Unit | ||
Ch/Unit | 2ch | |
Measurement range | Temperature: -200 to 1300℃ (Type K) | |
Voltage: ±12V | ||
Sampling interval | 100 msec to 10 min interval | |
Measurement unit power supply | Lithium metal primary battery | |
Dust proof/water proof | Use water-proof attachment | |
Measurement unit size | 54.5 (W) x 45 (D) x 17.5 (H) mm | |
Applicable thermocouple | Type K, Type T, Type J | |
Data display | Windows PC (Windows7, Windows8/8.1, Windows10) | |
Communication frequency | 2.4 GHz wireless communication |
* Windows is a registered trademark of Microsoft Corporation in the U.S. and/or other countries.
Other Functions
- Battery remaining level display function
- Radio wave strength display function
- Sensor disconnection check function
Available Country
Model | Old model | Current model |
---|---|---|
Country | Japan, China, Vietnam, Thailand | Japan, China, Vietnam, Thailand, United States, EU |
Image | ![]() | ![]() |
Products
To use this product, the following product is required for transmission control and receiving data.
PC Communication Unit: WM2000ZA-000-01
Please ask your representative for price
Standard products
Model | Description | Price |
---|---|---|
WM2000TA-000-01 (Calibration certificate not included) | 2 ch Temperature/Voltage Measurement Unit: 1 set Water-proof attachment: 1 set Lithium battery for trial use: 1 unit | Please contact your representative for price |
WM2000TA-000-05 (Calibration certificate not included) | 2 ch Temperature/Voltage Measurement Unit: 5 sets Water-proof attachment: 5 sets Lithium battery for trial use: 5 units | Please contact your representative for price |
WM2000TA-000-10 (Calibration certificate not included) | 2 ch Temperature/Voltage Measurement Unit: 10 sets Water-proof attachment: 10 sets Lithium battery for trial use: 10 units | Please contact your representative for price |
Options
Model | Description | Price |
---|---|---|
A7090-2000-TA | Calibration certificate (1 unit) *1 | Please contact your representative for price |
A7010-L10-010 | Replacement lithium battery: 10 units/set *2 | Please contact your representative for price |
A7010-L10-050 | Replacement lithium battery for replacement: 50 units/set *2 | Please contact your representative for price |
A7030-A00-010 | Replacement water-proof attachment: 10 units/set | Please contact your representative for price |
A7030-B00-001 | Heat-resistance case: 1 set *3 | Please contact your representative for price |
A7020 | Thermocouple Type K: 5 m | Please contact your representative for price |
*1 The price of one Calibration certificate is for one measurement unit. Please order number of measurement units required.
*2 Exclusive for Strain Measurement Unit (WM2000SA), 2 ch Temperature/Voltage Measurement Unit (WM2000TA), 7 ch Temperature/Voltage Measurement Unit (WM2000TB)
*3 Exclusive for 2 ch Temperature/Voltage Measurement Unit (WM2000TA), 7 ch Temperature/Voltage Measurement Unit (WM2000TB)
Example of Application
-
Evaluate solar Power generator
Measures temperatures, illuminations and voltages of solar power generators simultaneously to evaluate power generation efficiency
-
Measure reflow ovens
To set reflow conditions, or measure temperatures inside reflow ovens during inspection.
-
Measure brakes
Measures temperatures of disks during evaluation of brakes
-
Evaluate inside temperatures of servers
-
Evaluate inside temperatures of machine tools
-
Evaluate temperatures of vehicles